Product advantages
Large capacity
Up to 6x2400ml capacity, it can separate 14.4L samples in one cycle, significantly improving production efficiency.
Safe Structure
The overall unit has passed MCA (Maximum Credible Accident test ). After MCA is generated, the centrifuge door lid shall not be opened, and no solid greater than 0.5mm shall blown out of the centrifuge chamber; the position movement shall not exceed 30cm, ensuring the personal safety of the instrument operator to the greatest extent. (MCAtest video can be provided)
Reliable Material
Centrifuge chamber adopt 2mm thick 316L stainless steel, Housing (3mm Q235 steel ), Containment (22mm Q235 steel ), Diaphragm indoor lid (2.5mm Q235 steel)
Energy saving
Dynamic compressor control (DCC)technology for optimized cooling performance. When the door lid is opened, the compressor is closed, or the sleep time can be set to save energy. Rotor with windshield, little friction, and generates little heat.
Built-in safety
It features multiple protections, such as automatic rotor identification, imbalance protection, overspeed protection, overtemperature protection, motor overheating protection, and door lid protection.
Extensible
The system adopts a unified and standard Ethernet communication interface and provides a key parameter point table to facilitate system expansion and integrate data into system monitoring.
Programmable
Up to 2000 user-defined programs can be saved. Users can name each program to distinguish it. Each program can be divided into five steps(set speed, time, temperature ) to meet diversified experimental needs.
ACC/DEC Rates
We feature ten acceleration and 11 deceleration rates to prevent the sample from a second emulsion or turbid and achieve the best centrifugal effect.
Main interface function
In manual mode, the centrifuge parameters can be set quickly, and the G-force and speed can be switched by just touching the key. The curve for online monitoring of temperature and speed can be used to view the stability of temperature and speed during spinning.
Powerful System Setting Function
Running data, error code records, and operation records can be stored through the system setting. Chinese /English operation language is optional. User authority management and other characteristic functions can also be managed.
Technical parameter
Product Model | L720R-3 |
Refrigerated | |
Max Speed | Angle Rotor 7200r/min Swing Rotor 4000r/min |
Max RCF | Angle Rotor 12166xg Swing Rotor 5600xg |
Max Capacity | Angle Rotor 6x1000ml Swing Rotor 6x2400ml |
Time Setting Range | two-mode 1min-99h59min,1s-99min59s optional,default mode 1min-99h59min |
Timing mode | Start Timing after Spinning, Start Timing after each Setting Speed, Continuous Timing , Operationatan Appointed Time. |
Temperature Setting Range | -20℃~40℃, Setp 1℃ adjustable, The fast pre-cooling temperature can reach-20℃ |
Sample Temperature Accuracy | Ensure sample (liquid)temperature accuracy is controlled to ±1℃ |
Temperature Accuracy | ±2℃ |
Speed Accuracy | ±10r/min |
Power Supply | AC220±22V 50Hz |
Power Consumption | 7.0kW |
Noise | ≤65dB(A) |
Rotor Identification | Yes |
Imbalance Protection | Yes |
Pre-cooling function | Yes |
Computer Control | RS485 or RS232 |
Protection Function | Imbalance Protection, Rotor-identification, Door Lid Anti Pinch Protection, Motor Overheating Protection, Over-Speed Protection, Over-temperature Protection |
Dimension(WxDxH) | 875×1020×970(mm) |
Packing Dimension (WxDxH) | 1080×1310×1340(mm) |
Net Weigh | 545kg |
Rotor parameters